Made specifically for goats
A goat-specific pregnancy test using a blood sample.
Check whether your goat may be pregnant, with a blood-sample test.
Check whether your goat may be pregnant, with a blood-sample test.
Ask a veterinary professional.
Stand in shade: 30-45 min.
1 drop serum + 2 drops buffer.
Time from adding serum and buffer.
Record the result against the correct goat and breeding date. A negative screen is not an instruction to rebreed immediately.
Why this helps
Check pregnancy status to help plan breeding and pen space.
A goat-specific pregnancy test using a blood sample.
Prepare the serum first, then use the cassette and supplied buffer.
Record the result with the goat ID and mating date.
Count from breeding or AI
Note the breeding date before choosing when to test.

Count from the goat's mating date. Testing too early may miss a pregnancy.
Keep the blood tube upright in shade while the serum separates. This is not the result-reading time.
Count from adding serum and buffer. Do not interpret results after 20 minutes.
How to test
Test from 28 days after mating. Allow 30-45 minutes for serum preparation, then read 12-15 minutes after adding serum and buffer. Use one new cassette per goat. Have the supplied buffer and dropper ready.

Ask a veterinary professional to collect fresh blood into an appropriate serum collection tube. Handle blood and used materials safely.

Keep the blood tube upright and undisturbed in shade for 30-45 minutes. Do not shake. Use the clear serum above the settled blood.

Take clear serum without disturbing the blood below. Add 1 drop of serum to the sample well, followed by 2 drops of the supplied buffer. Do not add extra serum.

Start timing after adding serum and buffer. Read at 12-15 minutes. Do not interpret results after 20 minutes. Serum preparation is a separate step.
Understand the result
C is the control line and T is the test line. These are simplified guides, not photographs of the cassette.
Both C and T lines indicate a positive result, including a faint T line. Record the result and review it with your veterinarian.
Check the mating date and discuss the result with your veterinarian before making breeding decisions.
Use a new cassette and repeat the test, following each preparation step carefully.
Inside your pack
Keep cassettes sealed until use. Store at 2-30 degrees C, away from moisture. Do not freeze or reuse a cassette.
Questions farmers ask